OWON PC4711-W-TY UniClip Lite Wi-Fi Single-Phase DIN Rail Energy Meter
Wi-FiTuya



Key facts
| Type | Single-phase clamp-on (CT) energy meter, 35 mm DIN rail mounting |
|---|---|
| Connectivity | Wi-Fi 802.11 b/g/n at 2.4 GHz, with BLE for pairing |
| Platform / app | Tuya compliant, supporting automation scenarios and HA platform integration |
| Supported systems | Single-phase |
| CT clamps | Two CTs; 120 A (default, Ø16 mm), 80 A, 200 A and 300 A options |
| Measurement | Voltage, current, power factor, frequency, active power, reactive power and apparent power |
| Bidirectional / solar | Yes, bidirectional measurement of energy usage and solar production |
| Relay | No relay output |
| Accuracy | Voltage ±1%; current ±1% in the main range of each CT (see the CT table below) |
| Power supply | Power consumption below 2 W; 230 VAC, 50/60 Hz, 90-277 V range |
| Mounting | 35 mm DIN rail; 19 (W) × 69 (D) × 90 (H) mm |
| Certification | CE |
Features
- Tuya compliant, supporting automation scenarios and HA platform integration
- Single-phase electricity systems
- Remotely monitors a single-phase circuit or load with 2 current transformers
- Wi-Fi communication with fast configuration, suited to places where wiring is inconvenient
- Real-time voltage, current, power factor, frequency, active, reactive and apparent power
- Bidirectional measurement: energy usage and solar production
- Historical data displayed and exported in the app
- Offline energy data storage, reported automatically after the network reconnects
- Data erasure, remote reboot and CT setting functions
Specifications
| Wi-Fi | 802.11 b/g/n at 2.4 GHz |
|---|---|
| BLE | For pairing |
| Rated voltage | 230 VAC, 50/60 Hz |
| Voltage range | 90-277 V |
| Supported systems | Single-phase |
| Power consumption | Below 2 W |
| Voltage accuracy | ±1% |
| Current accuracy by CT |
|
| Clamp inner diameter |
|
| Reporting cycle | 15 seconds |
| Operating environment | -20 °C to +55 °C; humidity ≤ 90% non-condensing |
| Mounting | 35 mm DIN rail |
| Dimensions | 19 (W) × 69 (D) × 90 (H) mm |
| Certification | CE |
Applications
- Monitoring a single-phase circuit and a load, or two loads, in a distribution board
- Solar production and grid usage monitoring on single-phase systems
Notes
- Use a 2.4 GHz Wi-Fi network when adding the device to the app.
OWON smart energy meters can be supplied with Wi-Fi, Zigbee, 4G or LoRa communication. The meter models listed on this site are mainly Wi-Fi versions (Tuya-compliant or open API), plus the ZigBee PC311-Z-TY single-phase power clamp. If your project needs another Zigbee version, or a 4G or LoRa version, send your requirements to OWON sales.
PC4711-W-TY FAQ
What is the PC4711-W-TY?
The OWON PC4711-W-TY (UniClip Lite) is a Tuya-compliant Wi-Fi single-phase energy meter for DIN rail mounting. It uses two current transformers to monitor consumed and produced electricity, with real-time and historical data in the mobile app.
How does the PC4711-W-TY connect?
Connectivity: Wi-Fi 802.11 b/g/n at 2.4 GHz, with BLE for pairing.
Which electrical systems does the PC4711-W-TY support?
Supported systems: Single-phase.
Which CT clamps does the PC4711-W-TY use?
CT clamps: Two CTs; 120 A (default, Ø16 mm), 80 A, 200 A and 300 A options.
Can the PC4711-W-TY monitor solar production?
Bidirectional / solar: Yes, bidirectional measurement of energy usage and solar production.
Which app or platform works with the PC4711-W-TY?
Platform / app: Tuya compliant, supporting automation scenarios and HA platform integration.
Does the PC4711-W-TY have a relay?
Relay: No relay output.
What is the measurement accuracy of the PC4711-W-TY?
Accuracy: Voltage ±1%; current ±1% in the main range of each CT (see the CT table below).
How is the PC4711-W-TY powered?
Power supply: Power consumption below 2 W; 230 VAC, 50/60 Hz, 90-277 V range.
How is the PC4711-W-TY installed?
Mounting: 35 mm DIN rail; 19 (W) × 69 (D) × 90 (H) mm.
How can I get a quotation, samples or protocol documents for the PC4711-W-TY?
Email sales@owon.com or message OWON on WhatsApp (+86 13159213403) with your application, country and quantity. OWON sales can send the datasheet, quotation and, where applicable, protocol documents.
Related products
OWON PC311-Z-TY ZigBee Single-Phase Power ClampCompact ZigBee 3.0 single-phase clamp meterZigBeeTuya
OWON PC311-W-TY/N Wi-Fi Single-Phase Power ClampCompact Wi-Fi single-phase clamp meterWi-FiTuya
OWON PC4711-W-E-TY/R UniClip Pro Wi-Fi and Ethernet Single-Phase Energy Meter with RelayWi-Fi and Ethernet single-phase DIN rail clamp energy meter with dry contact relayWi-FiTuya
OWON PC4713-W-485 Open API Smart Energy MeterDIN rail three-phase energy meter with Open API (Wi-Fi and RS485)Wi-FiRS485 / EthernetOpen APIWhere this fits
- Solar and grid energy monitoring
- Multi-circuit sub-metering
- Compare OWON smart energy meters
- All Smart Energy Meters
- Protocols and integration options
- OEM / ODM customization
- Application examples
Guides
- How to Install a Single-Phase DIN Rail Energy Meter and Check CT Direction: OWON PC4711Step-by-step installation of the OWON PC4711 single-phase DIN rail energy meter: DIN rail mounting, power terminal, two CT clamps, arrow...
- Single-Phase vs Three-Phase Smart Energy MetersLearn the difference between single-phase, split-phase and three-phase energy monitoring, and which smart meter type fits a home, building...
- How to Choose a Smart Energy Meter: A Buyer's ChecklistA practical checklist for choosing a smart energy meter: supply type, CT rating, accuracy, communication, integration and certifications...
Solutions using this product
Installation video
Wiring and installation of the OWON PC4711 single-phase DIN rail energy meter: mounting on the rail, connecting the power terminal, fitting the two CTs and checking the readings.
Watch on YouTube: Single Phase DIN Rail Energy Meter Wiring & Installation | OWON PC4711
Steps shown in the video
- Turn off the circuit breakers and confirm there is no voltage on the terminals.
- Mount the meter on the 35 mm DIN rail.
- Connect the power terminal L/N in parallel to the L/N lines at the breaker output.
- Plug CT1 into the IA port and CT2 into the IB port of the CT terminal, "+" to IA+/IB+ and "-" to IA-/IB-.
- Place CT1 on the live wire of the main circuit and CT2 on the live wire of a load, arrow pointing towards the load.
- Insert the power and CT terminals into the meter, then turn the breakers on.
Related pages
- How to install the PC4711 and check CT direction
- Compare OWON smart energy meters
- PC4713 Open API: HTTP, MQTT, Modbus TCP and RS485 Modbus RTU
- EdgeEco IoT Platform: Four Ways to Integrate OWON Devices and Gateways
- Three Cloud Options for OWON Smart Energy Meters: OWON Cloud, Private MQTT and Tuya Cloud
- Tuya and Smart Life Integration for OWON Meters and Thermostats
Request a quotation for the PC4711-W-TY
Tell us your application, target market and quantity. Our sales team replies with datasheets, protocol documents and pricing.
Send an enquiry WhatsApp +86 13159213403Or email sales@owon.com