Heat Pump and Dual Fuel Wi-Fi Thermostats: What to Check

Short answer: OWON PCT513-TY, PCT5231-W-TY and PCT533-W-TY datasheets list heat pump support with 2-stage heating, 2-stage cooling, auxiliary heat and a reversing valve (O/B) terminal. Dual fuel or hybrid heat switching is listed for all three, and emergency heat is listed for heat pump systems.

What does a heat pump thermostat need to do?

A heat pump thermostat must control the compressor stages, the reversing valve (O/B) and any auxiliary or emergency heat, and avoid running expensive auxiliary heat when the heat pump alone can do the job. Dual fuel systems add a second heat source, such as a gas furnace, and switch between the two.

What do the OWON datasheets list?

ItemPCT513-TYPCT5231-W-TYPCT533-W-TY
Conventional systems2-stage heating, 2-stage cooling2-stage heating, 2-stage cooling2-stage heating, 2-stage cooling
Heat pump2-stage heating, 2-stage cooling, 2 aux heating2-stage heating, 2-stage cooling, 2-stage auxiliary or alternative heating, emergency heat2-stage heating, 2-stage cooling, 2-stage auxiliary or alternative heating, emergency heat
Dual fuel / hybrid heatListedListedListed
Reversing valve terminalO/BO/BO/B

How do I wire a heat pump, aux heat, emergency heat or dual fuel?

These wiring examples are based on the OWON PCT5231-W-TY Quick Start Guide. A two-stage heat pump uses Rc, Y/Y1, Y2, O/B, G, and C. Depending on the HVAC configuration, W/W1 and W2/E may be used for auxiliary heating, emergency heating, or a secondary heat source in a dual-fuel system. Follow the wiring diagram and configuration instructions for the specific system.

OWON PCT5231-W-TY wiring: 2-stage heat pump with 2-stage aux heat, and 2-stage heat pump with aux heat and emergency heat, using Rc, Y/Y1, Y2, O/B, G, C, Rh, W/W1 and W2/E
2-stage heat pump with 2-stage aux heat, and with aux heat and emergency heat (PCT5231-W-TY quick start guide).
OWON PCT5231-W-TY wiring: dual fuel with a 2-stage heat pump and 2-stage heat
Dual fuel: 2-stage heat pump with 2-stage heat (PCT5231-W-TY quick start guide).

The PCT533-W-TY quick start guide shows the same examples, with the additional ACC1 and ACC2 terminals for HVAC accessories.

What if I need custom switching logic?

For equipment manufacturers who need their own control logic, for example a heat pump and furnace switching on outdoor temperature, OWON can customize thermostat firmware as an ODM project. See the OEM and ODM page for a hybrid thermostat example.

Related OWON products

OWON PCT513 Wi-Fi Touchscreen ThermostatOWON PCT513 Wi-Fi Touchscreen Thermostat4.3-inch Wi-Fi touchscreen thermostat, up to 16 remote zone sensorsWi-FiTuyaOWON PCT5231 Wi-Fi 24 VAC ThermostatOWON PCT5231 Wi-Fi 24 VAC ThermostatWi-Fi thermostat for most 24 V systems, up to 10 remote sensorsWi-FiTuyaOWON PCT533 Tuya Wi-Fi Thermostat with Remote Sensors and Humidity ControlOWON PCT533 Tuya Wi-Fi Thermostat with Remote Sensors and Humidity Control4.3-inch Tuya Wi-Fi thermostat with humidifier / dehumidifier controlWi-FiTuya

Frequently asked questions

Do OWON Wi-Fi thermostats support emergency heat?

The PCT513-TY datasheet lists Emergency Heat for heat pump systems, and the PCT5231-W-TY and PCT533-W-TY datasheets list emergency heat as well.

Can they run a dual fuel system?

Yes. The datasheets list dual fuel switching or hybrid heat support. Confirm the wiring of your equipment with a qualified installer.

Related guides

Last updated: . Published by Xiamen OWON Technology Co., Ltd., the manufacturer of the products described. Reviewed by David Huang, Product Manager.

Talk to OWON about your project

Tell us your application, target market and quantity. Our sales team replies with datasheets, protocol documents and pricing.

Send an enquiry WhatsApp +86 13159213403

Or email sales@owon.com