24 VAC Thermostat Wiring Terminals Explained: R, C, W, Y, G and O/B
What do the terminals mean?
| Terminal | Usual meaning | Notes |
|---|---|---|
| R, Rc, Rh | 24 VAC power from the transformer (Rc for cooling, Rh for heating) | Systems with one transformer use a single R wire |
| C | Common wire, the return for 24 VAC power | Needed to power a Wi-Fi thermostat continuously |
| W1, W2 | Heating stage 1 and 2 | Gas, oil, electric or auxiliary heat |
| Y1, Y2 | Cooling stage 1 and 2 (compressor) | Also heat pump compressor |
| G | Fan | Blower control |
| O/B | Heat pump reversing valve | Energised in cooling (O) or heating (B), depending on the equipment |
| ACC1, ACC2 | Accessory control terminals for HVAC accessories | On the PCT5231-W-TY and PCT533-W-TY. Only the PCT533-W-TY provides 1-wire or 2-wire HUM / DEHUM control |
Which terminals do the OWON thermostats list?
| Thermostat | Terminals in the datasheet |
|---|---|
| PCT513-TY | RH, RC, C, W1, W2, Y1, Y2, G, O/B, S (optional wiring module terminal) |
| PCT5231-W-TY | Rc, Rh, C, W/W1 (AUX), W2/E (AUX2), Y/Y1, Y2, G, O/B, CWA (C-wire adapter terminal), ACC1, ACC2 |
| PCT533-W-TY | Rc, Rh, C, W1, W2, Y1, Y2, G, O/B, CWA, ACC1, ACC2 |
What Are the Wiring Terminals on the PCT5231-W-TY?
W/W1 (AUX) is the first-stage heat terminal and W2/E (AUX2) is the second-stage heat terminal. On a heat pump they carry auxiliary or alternative heat, and W2/E also carries emergency heat. ACC1 and ACC2 are accessory control terminals for HVAC accessories.
How do I connect more than one R wire?
| Wires you have | Wire to Rc terminal | Wire to Rh terminal |
|---|---|---|
| Rc and Rh | Rc | Rh |
| Rc and R | Rc | R |
| Rh and R | R | Rh |
With only one R wire (R, Rc or Rh), connect it to the Rc terminal. An E (emergency heat) wire goes to the W2 terminal. Source: PCT5231-W-TY quick start guide.
How many stages do they support?
According to the datasheets, all three thermostats support conventional systems with 2-stage heating and 2-stage cooling, and heat pump systems with 2-stage heating and 2-stage cooling plus auxiliary heat. The PCT513-TY datasheet lists 2 auxiliary heating stages and emergency heat for heat pumps.
Before you buy
- Photograph your existing thermostat wiring and note every terminal in use.
- Confirm the system is 24 VAC. Line-voltage systems such as electric baseboard heaters need a different thermostat.
- Count the heating and cooling stages, and check whether the system is a heat pump.
- Check for a C-wire; see the guide on thermostats without a C-wire.
Related OWON products
OWON PCT513 Wi-Fi Touchscreen Thermostat4.3-inch Wi-Fi touchscreen thermostat, up to 16 remote zone sensorsWi-FiTuya
OWON PCT5231 Wi-Fi 24 VAC ThermostatWi-Fi thermostat for most 24 V systems, up to 10 remote sensorsWi-FiTuya
OWON PCT533 Tuya Wi-Fi Thermostat with Remote Sensors and Humidity Control4.3-inch Tuya Wi-Fi thermostat with humidifier / dehumidifier controlWi-FiTuyaFrequently asked questions
Can I use a 24 VAC thermostat on line-voltage baseboard heaters?
No. Line-voltage baseboard heaters (120 V or 240 V) need a line-voltage thermostat. The OWON PCT513-TY, PCT5231-W-TY and PCT533-W-TY are for 24 VAC systems.
What is the O/B terminal?
It controls the reversing valve of a heat pump. Some manufacturers energise it in cooling (O) and others in heating (B). Check your equipment documentation.
Related guides
- Smart Thermostat Compatibility Checklist for Europe and North AmericaCheck smart thermostat compatibility before you buy: 24 VAC wiring and C-wire in North America, boiler and heat pump interfaces in Europe...
- Wi-Fi Thermostat Without a C-Wire: Options for 24 VAC SystemsWhat to do when a 24 VAC system has no C-wire: the OWON SWB511 power module (C-wire adapter), which supports the PCT513-TY, PCT5231-W-TY...
Talk to OWON about your project
Tell us your application, target market and quantity. Our sales team replies with datasheets, protocol documents and pricing.
Send an enquiry WhatsApp +86 13159213403Or email sales@owon.com