OWON PC341-W-TY/N Wi-Fi Multi-Circuit Energy Monitor
Wi-FiTuyaKey facts
| Type | Multi-circuit clamp-on (CT) energy monitor, wall or DIN rail mounting |
|---|---|
| Connectivity | Wi-Fi 802.11 b/g/n at 2.4 GHz, with BLE for pairing and an external magnetic antenna |
| Platform / app | Tuya compliant (automation with other Tuya devices by exporting and importing grid or other energy values) |
| Supported systems | Single-phase, split-phase and three-phase up to 480Y/277 VAC (the datasheet notes: no Delta / wye / Y / Star connection) |
| CT clamps | Main CTs: 200 A (default, Ø20 mm), 300 A / 500 A optional. Sub CTs: 50 A (default, Ø10 mm), 80 A / 120 A optional; up to 16 sub CTs |
| Measurement | Voltage, current, power factor, active power and frequency |
| Bidirectional / solar | Yes, bidirectional measurement of energy usage and solar production |
| Relay | No relay output is listed on the datasheet |
| Accuracy | Voltage ±1%; 200 A CT ±1% (2–200 A) and ±2% (0–2 A); 50 A CT ±1% (1–50 A) and ±2% (0–1 A) |
| Power supply | Power consumption below 2 W |
| Mounting | Wall or DIN rail mounting |
| Certification | CE |
Features
- Tuya compliant, with automation with other Tuya devices by export and import of grid or other energy values
- Single-phase, split-phase and three-phase (up to 480Y/277 VAC) systems
- Monitors whole-home energy and up to 16 individual circuits with 50 A sub CTs, such as solar, lighting and receptacles
- Wi-Fi 2.4 GHz wireless communication
- Real-time voltage, current, power factor, active power and frequency
- Bidirectional measurement: energy usage and solar production
- Historical data displayed and exported in the app
- External antenna prevents the signal from being shielded
Specifications
| Wi-Fi | 802.11 b/g/n at 2.4 GHz |
|---|---|
| BLE | For pairing |
| RF characteristics |
|
| Operating voltage (RMS per phase) | 90–277 Vac, 50/60 Hz |
| Supported systems |
|
| Power consumption | Below 2 W |
| Voltage accuracy | ±1% |
| Current accuracy |
|
| Clamp inner diameter |
|
| Main CT |
|
| Sub CT |
|
| Reporting cycle | Every 15 seconds |
| Operating environment | -20 °C to +55 °C; humidity ≤ 90% non-condensing |
| Mounting | Wall or DIN rail mounting |
| Certification | CE |
Standard PC341 models
| Model | System | Main CTs | Sub CTs |
|---|---|---|---|
| PC341-W-TY/200A*2 | Split-phase (US) | 2 × 200 A | None |
| PC341-W-TY/200A*2/50A*16 | Split-phase (US) | 2 × 200 A | 16 × 50 A |
| PC341-W-TY/200A*3 | 3-phase (EU) | 3 × 200 A | None |
| PC341-W-TY/200A*3/50A*16 | 3-phase (EU) | 3 × 200 A | 16 × 50 A |
Applications
- Sub-metering individual circuits such as solar, lighting and receptacles
- Whole-home energy monitoring with circuit-level detail
- Split-phase (US) and three-phase (EU) installations
Notes
- Use a 2.4 GHz Wi-Fi network when adding the device to the app.
PC341-W-TY/N FAQ
What is the PC341-W-TY/N?
The OWON PC341-W-TY/N is a Tuya-compliant Wi-Fi multi-circuit energy monitor. It measures whole-home energy with main CTs and up to 16 individual circuits (such as solar, lighting and receptacles) with 50 A sub CTs, and supports single-phase, split-phase and three-phase systems up to 480Y/277 VAC.
How does the PC341-W-TY/N connect?
Connectivity: Wi-Fi 802.11 b/g/n at 2.4 GHz, with BLE for pairing and an external magnetic antenna.
Which electrical systems does the PC341-W-TY/N support?
Supported systems: Single-phase, split-phase and three-phase up to 480Y/277 VAC (the datasheet notes: no Delta / wye / Y / Star connection).
Which CT clamps does the PC341-W-TY/N use?
CT clamps: Main CTs: 200 A (default, Ø20 mm), 300 A / 500 A optional. Sub CTs: 50 A (default, Ø10 mm), 80 A / 120 A optional; up to 16 sub CTs.
Can the PC341-W-TY/N monitor solar production?
Bidirectional / solar: Yes, bidirectional measurement of energy usage and solar production.
Which app or platform works with the PC341-W-TY/N?
Platform / app: Tuya compliant (automation with other Tuya devices by exporting and importing grid or other energy values).
Does the PC341-W-TY/N have a relay?
Relay: No relay output is listed on the datasheet.
What is the measurement accuracy of the PC341-W-TY/N?
Accuracy: Voltage ±1%; 200 A CT ±1% (2–200 A) and ±2% (0–2 A); 50 A CT ±1% (1–50 A) and ±2% (0–1 A).
How is the PC341-W-TY/N powered?
Power supply: Power consumption below 2 W.
How is the PC341-W-TY/N installed?
Mounting: Wall or DIN rail mounting.
How can I get a quotation, samples or protocol documents for the PC341-W-TY/N?
Email sales@owon.com or message OWON on WhatsApp (+86 13159213403) with your application, country and quantity. OWON sales can send the datasheet, quotation and, where applicable, protocol documents.
Related products
Guides
- How to Choose the Right CT Clamp Size for a Smart Energy MeterLearn how to choose a CT clamp rating and inner diameter for clamp-on smart energy meters, with the OWON CT options and accuracy bands from...
- Monitoring Solar Production and Grid Usage with Clamp-On Smart Energy MetersHow bidirectional smart energy meters track grid import, export and solar production, and which OWON meters list this function on their...
- Single-Phase vs Three-Phase Smart Energy MetersLearn the difference between single-phase, split-phase and three-phase energy monitoring, and which smart meter type fits a home, building...
Solutions using this product
- Solar and Grid Energy Monitoring with Clamp-On Smart Energy Meters
- Multi-Circuit and Sub-Metering with OWON Energy Meters
Request a quotation for the PC341-W-TY/N
Tell us your application, target market and quantity. Our sales team replies with datasheets, protocol documents and pricing.